DGS-3100 Series Gigabit Stackable Managed Switch User Manual
11
2
Defining Bandwidth Settings
The Bandwidth Control Page allows network managers to define the bandwidth settings for a specified interface.
1. Click QoS > Bandwidth Control. The Bandwidth Control Page opens:
Figure 4-2. Bandwidth Control Page
The Bandwidth Control Page contains the following fields:
Field Description
Unit
Defines the stacking member for which the bandwidth parameters are displayed
From Port
Defines from which port number bandwidth settings are displayed.
To Port
Defines to which port number bandwidth settings are displayed.
RX No Limit
Defines if ingress bandwidth limitation is assigned to the port. The field value
options are:
Enabled — Ensures no bandwidth limitations on the port. (This is the default
value).
Disabled —Enables ingress bandwidth limitations on the port. When
disabled, user can enter a limit value in the RX Rate field.
RX Rate (3500-1000000) kbps
Specifies the maximum ingress rate on the port. The possible field range is
3500 – 1000000 Kbps
TX No Limit
Specifies whether egress bandwidth limitation applies to the port. The possible
field values are:
Enabled — Specifies no egress bandwidth limitations on the port. (This is the
default value).
Disabled —Enables egress bandwidth limitations on the port. When disabled,
the user can enter a limit value in the TX Rate field.
TX Rate (64-1000000) Kbps
Specifies the maximum egress rate on the port. The possible field range is 64 –
1000000 Kbps.