DES-3226 NWay Standalone Fast Ethernet Switch User’s Guide
Figure 7-42. Tx Packets Analysis window (Table)
The information is described as follows:
Time Interval [1s ] – Select the desired setting between 1s and 60s, where “s” stands for
seconds. The default value is one second.
Record Number [200 ] – Select number of times the Switch will be polled between 20 and 200.
The default value is 200.
Bytes – Counts the number of bytes successfully sent from the port.
Packets – Counts the number of packets successfully sent on the port.
Show/Hide – Check whether or not to display Bytes and Packets.
Clear – Clicking this button clears all statistics counters on this window.
View Table – Clicking this button instructs the Switch to display a table rather than a line
graph.
View Line Chart – Clicking this button instructs the Switch to display a line graph rather than a
table.
Errors
The Web Manager allows port error statistics compiled by the Switch’s management agent to be viewed
as either a line graph or a table. The four windows offered are as follows: