DVG-3016S/3032S Users Manual Dialing Principles
D-Link Systems, Inc. 64
5. Dialing Principles
5-1 Dialing Options
1. Dial the phone number which you want to call and press # to call out immediately, or wait until the “Inter
Digits Timeout” expires (defined in “Advanced Options”, default=4 seconds, see page 25).
2. If the phone number fits the setting of the Digit Map, the gateway dials out the phone number through the
assigned interface automatically.
3. The phone number should have at least 2 digits (not including * and #).
5-2 Dialed Number Processing Flow
To maintain maximum flexibility, the number dialed will be looked up in several tables defined by the
gateway. If no match is found, it will look up the number from the registered SIP Proxy Server. The number
look up flow is shown below:
A complete flow chart is shown on the next page.
Digit Map
Table
Extension
Number
Local Phone
Book
Phone Book
Mana
g
e
r
SIP
Prox
y