D-Link DGS-3700 User Manual Page 97

  • Download
  • Add to my manuals
  • Print
  • Page
    / 292
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 96
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual
86
Leave All Time
(100-100000)
The time in milliseconds that specifies the amount of time the Switch will take to Leave All
groups. The default is 10000. The Leave All Time must be greater than the Leave Time.
NNI BPDU
Address
This specifies the GVRP’s pdu MAC address of the NNI port.
Dot1d Specifies GVRPs pdu MAC address of NNI port using 802.1d.
Dot1ad Specifies GVRPs pdu MAC address of NNI port using 802.1ad.
Click Apply to implement changes made.
MAC-based VLAN Settings
This table is used to create MAC-based VLAN entries on the switch. A MAC Address can be mapped to any existing
static VLAN and multiple MAC addresses can be mapped to the same VLAN. When a static MAC-based VLAN entry
is created for a user, the traffic from this user is able to be serviced under the specified VLAN regardless of the
authentiucation function operated on the port. Therefore each entry specifies a relationship of a source MAC address
with a VLAN.
To view this window, click L2 Features > MAC-based VLAN Settings as shown below:
Figure 3 - 21 MAC-based VLAN Settings window
The following fields can be set
Parameter Description
MAC Address Specify the MAC address to be reauthenticated by entering it into the MAC Address field.
VLAN Name
Enter the VLAN name of a previously configured VLAN.
Click Find, Add or Delete All for changes to take affect.
PVID Auto Assign Settings
This commands Enables or Disables PVID Auto Assign on the Switch. PVID is the VLAN that the switch will use for
forwarding and filtering purposes. If PVID Auto-Assign is Enabled, PVID will be possibly changed by previously set
PVID or VLAN configurations. When a user configures a port to VLAN Xs untagged membership, this port’s PVID will
be updated with VLAN X. In the form of a VLAN list command, PVID is updated with the last item on the VLAN list.
When a user removes a port from the untagged membership of the PVID’s VLAN, the port’s PVID will be assigned to a
default VLAN. When PVID Auto Assign is Disabled, PVID can only be changed by PVID configuration (user changes
explicitly). The VLAN configuration will not automatically change the PVID. The default setting is Enabled.
To view this window, click L2 Features > PVID Auto Assign Settings as shown below:
Figure 3 - 22 PVID Auto Assign Settings window
Page view 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 291 292

Comments to this Manuals

No comments